ID CP1276224
819 mp HalaA+zona Sag, !
ID CP1276224
3,276 € + 19% TVA
Warehouse
STRUCTURAL SYSTEM
• Reinforced Concrete and Structural Steel;
• Dimensions as per project drawings;
WALLS
• Edge walls made of sandwich panels having a thickness of 100mm;
• Precast concrete wall panels (for docking areas);
ROOF
• Sandwich panels with corrugated steel sheets and rock wool insulation;
• Roofing membrane warranty period of 15 years;
• Smoke hatches/outlets according to national norms and regulations;
LOADING DOCKS
• Industrial sectional doors with thermal insulation sections;
• Sectional doors: 2.8m x 3m surface with electronic control and glazing - loading
docks
• Dock levelers: electronic control and cylinder hydraulic system (rated load of 60kN);
• Buffers: 2 rubber buffers for each loading dock;
• Stainless steel wheel guides;FLOORS
• Imposed load of 4 tons / m2
;
• Polished concrete flooring;
• Flatness tolerance of 3mm below 2 m, below the 2 m bar;
FIRE DETECTION SYSTEM
• Fire alarm with central unit and control panel;
• Evacuation alarm through fire bells;
• Overground valve hydrants on the perimeter of the unit;
• Sprinkler system with normal fire sprinkler heads;
POWER PLANTS
• Capacity: approx. 70kW/unit;
• Power supply on medium voltage;
• Power sockets (TBD);
Page 5 of 5
LIGHTHING SYSTEMS
• Lighting levels of about 200 lux measured at 1m AFL (Above Floor Level) for
warehouse areas;
• Emergency escape lighting system on escape routes;
• Industrial lighting system with LED lamps;
HEATING SYSTEMS
• Destratification fans on gas;
• Minimum temperature of 5 °C when external temperature is -20 °C;
Warehouse office areas
PARTITION WALLS
• Floors: reinforced concrete;
• Tarket and ceramic tiles depending on the area;
PARTITION WALL SPECIFICATIONS
• Drywall partition system with white washable finish;
• MDF (Medium Density Fiberboard) interior doors;
CEILING
• Clear height of 2.7 m;
• Mineral fibre acoustic ceilings;
Page 6 of 5
LIGHTHING SYSTEMS
• 60 x 60 cm recessed LED panel lights;
• Emergency escape lighting system on escape routes;
• 500 lux for office areas;
• 250 lux for hallways and staircases;
• 150 lux for sanitary areas;
HVAC SYSTEMS
• Multi-split cooling system;
• Heat electric radiators;
• Hot water electric boilers;
• Minimum temperature of 20 °C warranty when external temperature is
-20 °C;
• Cooling capacity 5°C below external temperature;
POWER SOCKETS
• 3 power sockets per every 15 m2 of office space;
Outer site
• Green areas and water supply according to local norms and regulations;
• Roads and parking spaces either paved with concrete clinkers or asphalt;
• Parking lot (according to project drawings);
• LED outer lighting system with a 10-lux illumination level measured at 10 m away from the
unit;
FLOORS
• Imposed load of 4 tons / m2
;
• Polished concrete flooring;
• Flatness tolerance of 3mm below 2 m, below the 2 m bar;
FIRE DETECTION SYSTEM
• Fire alarm with central unit and control panel;
• Evacuation alarm through fire bells;
• Overground valve hydrants on the perimeter of the unit;
• Sprinkler